Page 34
Installation | Housing L
optoNCDT 2300
5.4 Housing L
ILD2310-50
ILD2310-50BL
Bolt connection Direct fastening
3.5 Nm
5 Nm
8 ... 10
Housing Through
length
Screw Washer Tightening
torque per
screw
Screw depth Screw Tightening
torque per
screw
ISO 4762-A2 ISO 7089-A2 µ = 0.12 Minimum Maximum ISO 4762-A2 µ = 0.12
mm Nm mm mm Nm
L 48 M5 A5.3 3.5 9.6 10 M6 5
Fig. 13 Mounting conditions housing size L
Recommended tightening torque
max. + 10 % permissible, not deceed min. -20 %!
The tightening torques specified in the table are approximate and may vary depending on the application.
The bearing surfaces surrounding the through-holes (mounting-holes) are slightly raised.
i
Mount the sensor only to the existing through-holes on a flat surface. Clamps of any kind are not permitted.
Housing sizes, see Chap. 3.4.