5.6.5 Ethernet
To connect the sensor via the Ethernet interface the internet protocols TCP and UDP are used. This requires generally a PC with a web
browser such as Mozilla Firefox and a free Ethernet interface or a network connection. Standard protocol is TCP/IP.
Connect the sensor to a PC via a direct Ethernet connection (LAN) or Switch (Intranet). Therefore use a LAN cable with RJ-45-
male connectors and the optionally available cables PC2300-x/SUB-D and PC2300-0.5/Y.
PC2300-0.5/Y
Patch cable
PC2300-x/SUB-D
optoNCDT
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 20xx-xx
P 1mW; P 1.2mW; t=0.5...542 s
0 P
≤ ≤ μ
F=1.5...50kHz;
=670nm
PS2020
230 VAC
PE
N L