5.2 Housing S
ILD2300-2 ILD2300-5 ILD2300-10 ILD2300-20 ILD2300-50 ILD2300-100
ILD2300-2LL ILD2300-10LL ILD2300-20LL ILD2300-50LL
ILD2300-2BL ILD2300-5BL ILD2300-10BL
Bolt connection
Housing Through
length
Screw Washer Tightening
torque per
screw
1.5 ... 2 Nm
ISO 4762-A2 ISO 7089-A2 µ = 0.12
mm Nm
S 30 M4 A4.3 2
S (weight-reduced) 30 M4 A4.3 1.5
Fig. 7 Mounting conditions housing size S
Recommended tightening torque
max. + 10 % permissible, not deceed min. -20 %!
The tightening torques specified in the table are approximate and may vary depending on the application.
The bearing surfaces surrounding the through-holes (mounting-holes) are slightly raised.
i
Mount the sensor only to the existing through-holes on a flat surface. Clamps of any kind are not permitted.
Housing sizes, see Chap. 3.4.