EasyManua.ls Logo

MICRO-EPSILON optoNCDT 2300 - Page 29

MICRO-EPSILON optoNCDT 2300
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 29
Installation | Housing S
optoNCDT 2300
Diffuse Reflection
If the laser beam does not strike the object surface at a
perpendicular angle, measurements might be inaccu-
rate.
Mount the sensor using the through-bores and
three M4 screws from the accessories.
MR SMR Y
2 (.08) 24 (.94) 1.5 (.06)
5 (.20) 24 (.94) 3.5 (.14)
10 (.39) 30 (1.18) 6.5 (.26)
20 (.79) 40 (1.57) 10.0 (.39)
50 (1.97) 45 (1.77) 23.0 (.91)
100 (3.94) 70 (2.76) 33.5 (1.32)
MR = Measuring range
SMR = Start of measuring range
Dimensions in mm (inches)
67 (2.64)
33.5 (1.32)
4
4.5
89 (3.50)
97 (3.82)
SMR
75 (2.95)
4
Y
10
MR
48
2
Keep this area free from
other light sources and/or
their reflections
Through-holes
ø4.5
for M4 screws
30 (1.18)
15 (0.59)
7 7
Limits for free
space
Laser
13.5
Fig. 8 Dimensional drawing, free space for diffuse reflection

Table of Contents