Page 94
Value Output
optoNCDT 2300
9. Value Output
The optoNCDT 2300 outputs the measurements are either via the RS422 or Ethernet. Both output types can not be used simultane-
ously.
Video
signals
Temperature Shutter
time
Profile
counter
Time
stamp
Trigger
counter
Measure-
ments
Error
field
Differences Statistics
RS422
1)
x x x x x x x x
Ethernet x x x x x x x x x x
Fig. 48 Existing output values for the interfaces
i
Use the commands GETOUTINFO_ETH and GETOUTINFO_RS422 to check the set output values at the interfaces, see Chap. A
6.5.2.1.
9.1 RS422
The digital measurement values are issued as unsigned digital values (raw values). 16 Bit per value are transmitted. One or two 16-bit
values are transmitted. Examples: a displacement value or two displacement values or a displacement value plus an optional reading
or two optional readings. The formula also applies to values that are encoded with 18 bits, see Chap. 8.3.
Value range
0 ... 65519 (16 Bit - 16) Calculation of a measurement value in mm from digital output
0 ... 642 SMR back-up
x [mm]= digital
OUT
- 0.01 Measuring range [mm]
*
*
1.02
65520
x [mm]= digital
OUT
- 0.51 Measuring range [mm]
*
*
1.02
643 ... 64876 Measurement range
64877 ... 65519 EMR back-up
Fig. 49 Calculation and output of distance values
x [mm]= digital
OUT
measuring range [mm]
*
*
1.02
65520
Fig. 50 Calculation of thickness values
1) Reference is start of measuring range, distance measurement, thickness measurement
2) If Mastering is used only distance measurement