Page 78
Control Menu, Set Sensor Parameter
optoNCDT 2300
7.6.2.6 Function
How the data output is assigned, depends on the selected trigger output.
Command TRIGGEROUT TRIGGERED
Trigger signal
1 1 1 1 1 1 1 1 1 1 1
0 0 0 0 1 1 1 1 1 1 2
0 1 2 3 0 1 2 3 4 5 0
Measurements
T
Trigger event counter
Trigger measurement counter
Command TRIGGEROUT ALL
Trigger signal
1 1 1 1 0 0 0 0 0 0 0 0 01 1 1 1 1 1 1 10
0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2
0 1 2 3 0 1 2 2 2 23 3 3 0 1 2 3 4 4 4 4 4
Measurements
T
Trigger event counter
Trigger measurement counter