Appendix| EtherCAT
optoNCDT 2300
0 – Ethernet (works only from restarting, previously setup store)
1 – EtherCAT
Save the settings with the object 2010:02 (setup store). Restart the sensor for activating the Ethernet interface subsequently.
Subindices 5…18: Data selection for the PDO mapping
Distance 1, Distance 2 and Difference 1-2 are not selectable, these values are selected automatically according to the selected mea-
surement program.
A 7.3.3.12 Object 21C0h: Ethernet
21C0 RECORD Ethernet
Subindices
0 VAR Number of entries 8 Unsigned8 ro
1 VAR IP address xxx.xxx.xxx.xxx Visible String rw
2 VAR Subnet mask xxx.xxx.xxx.xxx Visible String rw
3 VAR Gateway xxx.xxx.xxx.xxx Visible String rw
4 VAR DHCP FALSE BOOL rw
5 VAR Measured value server protocol 0x00 (0) Unsigned8 rw
6 VAR Measured value server IP address xxx.xxx.xxx.xxx Visible String rw
7 VAR Measured value server port x Unsigned16 rw
8 VAR MAC address xxx.xxx.xxx.xxx Visible String ro
Further details can be found in the section Ethernet and Setting Measurement Server, see Chap. A 6.3.4.1, see Chap. A 6.3.4.2.