Page 37
Installation | Housing 2DR
optoNCDT 2300
The sensor must be mounted according to the installation drawing so
that the reflected beam hits the receiver.
90°
90°
Target/target surface
Mount the sensor by means of 3 screws type M3 or M4 from the
accessories.
Mounting steps
Switch on the power supply on the sensor.
Observe how the color of the Status LED
on the sensor changes.
- Position a reflective measuring object
near midrange.
Er
A
LED
Status
- The Status LED lights up yellow.
- Fasten the sensor using three M3 or M4
screws.
MR = Measuring range
Dimensions in mm (inches)
93 (3.66)
86 (3.39)
40.5 (1.59) 45.5 (1.79)
MR = 2
10 (.39)
17 x 45°
30 (1.18)
15
(.59)
88 (3.46)
3.5
(.14)
3.5
(.14)
95 (3.74)
90°
3x Through-holes
Fig. 16 Dimensional drawing, ILD2300-2DR/R,
ILD2300-2DR/BL