Page 70
Control Menu, Set Sensor Parameter
optoNCDT 2300
The synchronous inputs are used for external triggering. So
the sensors can alternatively be synchronized or triggered.
The change between synchronization (default setting) and
triggering is possible with the Web interface or ASCII com-
mand. Trigger source can be, for example, an encoder with
RS422-level or a level converter which resets the TTL / HTL
signals in RS422 level. Micro-Epsilon recommends the level
converter SU4-x from LEG Industrie-Elektronik, see appendix.
Maximum trigger rate £0.4 * measuring rate
U
I
Trigger
source
ILD 2300
5
6
2
GND
Fig. 39 Trigger wiring
Signal Sensor Extension cable PC2300
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Fig. 40 Sensor round
connector, view on
solder pin side male
cable connector
15-pol. Sub-D
GND 2 9
Trigger-in/out 5 3
/Trigger-in/out 6 11