3-4 PCWS 2015 Setup Guide - 2nd Edition
What’s Inside?
Disassembling the PCWS 2015
7. To remove the LCD/Touchscreen assembly, remove the following cables
from the System Board, then set the assembly to the right side.
Resistive Touchscreen
o Remove the LVDS data cable from J19 if you have not already.
o Remove the Backlight cable from J1.
o Remove the resistive touchscreen connector from J6.
Capacitive Touchscreen
o Remove the LVDS data cable from J19 if you have not already.
o Remove the Backlight cable from J1.
o Remove the capacitive touchscreen interface cable from J2.
For more information about each LCD/Touchscreen Assembly, see pages
3-30 and 3-31.
The PCWS 2015 Base
The PCWS 2015 base originates from the Workstation 5A, and adds about
10mm in overall height.
The 10mm increase in height combined with
a new copper bonding process to eliminate the faraday cage found in the
Workstation 5A, allows a pair of laptop form factor SATA II drives to be
installed in the base, under the System Board as shown in Figure 3-7.
The following pages show examples of the base with a Revision C or Revision
D system board installed and points out the changes.