Table18.21 Error messages on C Controller setting utility (Continued)
Error message Corrective action
The interrupt pointer No. is not set.
Please set the interrupt pointer with in the range of 50 - 255.
Enter the interrupt event within the range of 50 to 255.
The interrupt pointer No. value setting is out of range.
Please set the interrupt pointer with in the range of 50 - 255.
Enter the interrupt event within the range of 50 to 255.
The interrupt pointer range setting is overlapping.
Please correct the settings.
Set the interrupt event ranges without overlapping.
The IP address setting is out of the allowable address range.
Check the address range and set it again.
Set the IP address within the allowable range.
The minutes setting is out of range.
Please input with in the range of 0-59.
Enter a value within the range of 0 to 59.
The model name character string length exceeds 16 bytes.
Please use a model name with a length of 16 or fewer (single byte)
characters.
Set the model name using 16 characters or less.
The month setting is out of range.
Please input with in the range of 1-12.
Enter a value within the range of 1 to 12.
The No.of interrupt pointers is not set.
Please set the No.of interrupt pointers with in the range of 1 - 16.
Set the number of interrupt events within the range of 1 to 16.
The No.of interrupt pointers value setting is out of range.
Please set the No.of interrupt pointers with in the range of 1 - 16.
Set the number of interrupt events within the range of 1 to 16.
The power model name character string length exceeds 10 bytes.
Please input a model name with a length of 10 (single byte)
characters or less.
Set the model name using 10 characters or less.
The power model name character string length exceeds 10 bytes.
Please input a model name with a length of 10 (single byte)
characters or less.
Set the model name using 10 characters or less.
The project name has not been entered.
Enter the project name.
Specify the project name.
The remote operation has failed.
Error code: XX
Take corrective actions according to the error code. (Error list of the
bus interface function HELP)
The seconds setting is out of range.
Please input with in the range of 0-59.
Enter a value within the range of 0 to 59.
The set value is out of the word data range.
Enter a value within the range of -32768 to 32767.
Enter a value within the range of -32768 to 32767.
The set value of the switch is input excluding the binary number.
Please input by the binary number of 0 or 1.
Enter the switch setting value in binary.
The set value of the utility communication task (priority) is out of
range.
Set a value within the range of 99 to 255.
Set a value within the range of 99 to 255.
The setting date and time data are out of range.
Set data within the range from 00:00:00: on January 1st in 2000 to
23:59:59 on December 31st in 2099.
Set the clock within the range from 00:00:00, January 1, 2000 to
23:59:59, December 31, 2099.
The setting in the number of communication diagnosis is out of
range.
Set a value within the range of 1 to 32767.
Set it within the range of 1 to 32767.
The slot number is not set.
Please set the slot number.
Set the number of slots.
The specified file cannot be read because the C Controller setting
utility version is different.
Install the same C Controller setting utility version as the one used to
create the file.
The specified file is not a parameter file of the C Controller setting
utility.
Check the specified file.
The specified MD function timeout value is out of range.
Set a value within the range of 1 to 360.
Set it within the range of 1 to 360.