AUTOMATIC TRANSMISSION ± On-vehicle Service
23-38
INHIBITOR SWITCH AND CONTROL CABLE
ADJUSTMENT
1. Set the manual control lever to the N position.
2. Loosen the inhibitor switch mounting bolt.
3. Turn the inhibitor switch to align the N position reference
line on the inhibitor switch with the scratched line on the
N position adjusting plate.
4. Tighten the mounting bolt to the specified torque.
Tightening torque: 5.4 Nm
VCU LOCK DETECTION SWITCH CONTINUITY CHECK
Check the continuity between the terminal of the brown
connector installed in the side of transfer case (shown in the
illustration) and the transfer case.
Transfer lever position Continuity
4H No continuity
4HLc Continuity
2WD/4WD DETECTION SWITCH CONTINUITY CHECK
Check the continuity between the terminal of the white
connector installed in the side of transfer case (shown in the
illustration) and the transfer case.
Transfer lever position Continuity
2H Continuity
4H No continuity
VCU LOCK OPERATION DETECTION SWITCH
CONTINUITY CHECK
Check the continuity between the terminal of the brown
connector installed in the top of transfer case (shown in the
illustration) and the transfer case.
Transfer lever position Continuity
4H No continuity
4HLc Continuity
4WD OPERATION DETECTION SWITCH CONTINUITY
CHECK
Check the continuity between the terminal of the white
connector installed in the top of transfer case (shown in the
illustration) and the transfer case.
Transfer lever position Continuity
2H No continuity
4H Continuity
N position
reference
line
Mounting bolt
N position adjust-
ing plate