Calibrate the scanner
Introduction
To maintain a consistent quality of the output, the Océ TCS400 scanner
operator panel has a calibration wizard.
When to do
Use the scanner calibration wizard to get consistent output of high quality.
Between 2 scanner calibrations, the automatic scanner adjustment stabilizes
the output quality. The automatic scanner adjustment keeps the scanner
independent of changes in the environment.
Use the scanner calibration wizard to start a scanner calibration when the scan
quality decreases.
Use the scanner calibration wizard when the following error message appears
on the screen.
'Unable to align the cameras. Please calibrate the scanner.'
Before you begin
Turn on the scanner at least one hour before you do the scanner calibration
The scanner needs one hour to warm-up for optimal calibration.
Clean the glass plate of the scanner
(seeClean the scan area on page 197)
Clean the white platen of the scanner
(seeClean the scan area on page 197)
Clean the calibration sheet
The scanner operator panel must display 'Ready'.
Make sure the IT8 file matches the scanner calibration sheet.
(seeUpdate the IT8 file for scanner calibration’ on page 149)
Required tool
The scanner calibration sheet inside the front compartment.