3-48
3-9 Parameter List
3
Operation
Output terminal operation function
C130 Output 11 ON delay 0.0 to 100.0 0.0
No s 4-108
C131 Output 11 OFF delay 0.0 to 100.0 0.0
C132 Output 12 ON delay 0.0 to 100.0 0.0
C133 Output 12 OFF delay 0.0 to 100.0 0.0
C134 Output 13 ON delay 0.0 to 100.0 0.0
C135 Output 13 OFF delay 0.0 to 100.0 0.0
C136 Output 14 ON delay 0.0 to 100.0 0.0
C137 Output 14 OFF delay 0.0 to 100.0 0.0
C138 Output 15 ON delay 0.0 to 100.0 0.0
C139 Output 15 OFF delay 0.0 to 100.0 0.0
C140
Relay output ON delay
0.0 to 100.0 0.0
C141
Relay output OFF 
delay
0.0 to 100.0 0.0
C142
Logic output signal 1 
selection 1
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
C143
Logic output signal 1 
selection 2
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
Output terminal operation function
C144
Logic output signal 1 
operator selection
00: AND
01: OR
02: XOR
00
No  4-102
C145
Logic output signal 2 
selection 1
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
C146
Logic output signal 2 
selection 2
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
C147
Logic output signal 2 
operator selection
00: AND
01: OR
02: XOR
00
C148
Logic output signal 3 
selection 1
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
C149
Logic output signal 3 
selection 2
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
C150
Logic output signal 3 
operator selection
00: AND
01: OR
02: XOR
00
C151
Logic output signal 4 
selection 1
Same as options for C021 to C026 
(excluding LOG1 to LOG6)
00
Parameter 
No.
Function name Monitor or data range
Default 
setting
Changes 
during 
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 
to C008.