5-2 Warning Function
5
Maintenance Operations
5-2 Warning Function
•The following table shows the details of warning display and parameter correction.
Target code Condition Base code
Frequency upper limit A061/A261 >
Maximum frequency
A004/A204/A304
Frequency lower limit A062/A262 >
Base frequency A003/A203/A303
*1
>
Output frequency F001, Multi-step speed reference 0
A020/A220/A320
*2
>
Multi-step speeds 1 to 15 A021 to A035 >
Orientation speed setting P015 >
Frequency lower limit A062/A262 >
Frequency upper limit
A061/A261
Output frequency F001, Multi-step speed reference 0 A020/A220
*2
>
Multi-step speeds 1 to 15 A021 to A035 >
Frequency upper limit A061/A261
<
Orientation speed
P015
<
Frequency lower limit
A062/A262
Output frequency F001, Multi-step speed reference 0
A020/A220/A320
*2
<
Frequency upper limit A061/A261 <
Starting frequency
b082
Frequency lower limit A062/A262 <
Output frequency F001, Multi-step speed reference 0
A020/A220/A320
*2
<
Multi-step speeds 1 to 15 A021 to A035 <
Jogging frequency A038 <
Output frequency F001, Multi-step speed reference 0
A020/A220/A320
*2
< >
Jump frequency 1/2/3
± Jump width
A063 ± A064
A065 ± A066
A067 ± A068
*3
Multi-step speeds 1 to 15 A021 to A035 < >
Frequency upper limit A061/A261 >
Free V/f frequency 7 b112
Frequency lower limit A062/A262 >
Output frequency F001, Multi-step speed reference 0 A020/A220
*2
>
Multi-step speed reference 1 to 15 A021 to A035 >
Free V/f frequencies 1 to 6
b100, b102, b104, b106, b108, b110
>
Free V/f frequencies 2 to 6
b102, b104, b106, b108, b110
< Free V/f frequency 1 b100
Free V/f frequency 1 b100 >
Free V/f frequency 2 b102
Free V/f frequencies 3 to 6 b104, b106, b108, b110 <
Free V/f frequencies 1, 2 b100, b102 >
Free V/f frequency 3 b104
Free V/f frequencies 4 to 6 b106, b108, b110 <