4-111
4-2 Function Mode
4
Functions
AM/AMI Adjustment
Adjust the Inverter output gain according to the meters connected to the AM and AMI terminals.
Note: The offset data is set in %.
(Example) If AMI provides 4 to 20 mA output, the offset value is 20% (= 4/20). (Default value)
Operation Selection During Option Error
If the built-in optional board causes an error, you can set whether the Inverter trips or continues to
run regardless of the option error.
<Group H: Motor Control Parameters>
Offline Auto-Tuning Function
This function enables measurement and automatic setting of the motor parameters required for
"sensorless vector control", "0-Hz sensorless vector control", and "sensor vector control".
To perform "sensorless vector control", "0-Hz sensorless vector control", or "sensor vector control"
for a motor with unknown motor parameters, perform offline auto-tuning to determine the motor
parameters.
To use the online auto-tuning function described later, be sure to perform offline auto-tuning in
advance.
This function is applicable to 1st/2nd control, not to 3rd control.
For motor parameters, the Inverter inputs data on one phase of Y-connection at 50 Hz.
Parameter No. Function name Data Default setting Unit
C106 AM gain setting 50 to 200: Set a gain for the AM monitor. 100
%
C109 AM bias setting
0 to 100:
Set an offset for the AM monitor.
0
C107 AMI gain setting 50 to 200: Set a gain for the AMI monitor. 100
C110 AMI bias setting
0 to 100:
Set an offset for the AMI monitor.
20
Parameter No. Function name Data Default setting Unit
P001/P002
Operation selection at
option error
00: Trip
01: RUN (Continues operation)
00
Parameter No. Function name Data Default setting Unit
H001 Auto-tuning selection
00: OFF (Disabled)
01: ON (STOP)
02: ON (Rotation)
00
H002/H202 Motor parameter selection
00: Standard motor parameter
01: Auto-tuning parameter
02: Auto-tuning parameter
(Online auto-tuning enabled.)
00
H003/H203 Motor capacity selection 0.20 to 160.00 Factory default kW
H004/H204
Motor pole number
selection
2/4/6/8/10 4 Pole
H030/H230
Motor parameter R1
(auto-tuning data)
0.001 to 65.535
Depends on the
motor capacity.
H031/H231
Motor parameter R2
(auto-tuning data)
0.001 to 65.535
Depends on the
motor capacity.