4-220
4-4 Communication Function
4
Functions
* Data on H203 (2nd motor capacity selection) is the following code data.
<Holding Register Number List (3rd Setting)>
<Holding Register Number List (Function Mode 3rd Setting)>
2549h
to
3102h
Not used
Register
No.
Function name
Function
code
R/W Monitor and setting parameters Resolution
Code data 00 01 02 03 04 05 06 07 08 09 10
Motor capacity (kW) 0.2 0.4 0.75 1.5 2.2 3.7
Code data 11 12 13 14 15 16 17 18 19 20 21
Motor capacity (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Code data 22 23 24 25 26
Motor capacity (kW) 90 110 132 150 160
Register
No.
Function name
Function
code
R/W Monitor and setting parameters Resolution
3103h
3rd acceleration time 1
F302
(HIGH)
R/W
0.01 to 3600.00 0.01 [s]
3104h
F302
(LOW)
R/W
3105h
3rd deceleration time 1
F303
(HIGH)
R/W
0.01 to 3600.00 0.01 [s]
3106h
F303
(LOW)
R/W
3107h
to
3202h
Not used
Register
No.
Function name
Function
code
R/W Monitor and setting parameters Resolution
3203h 3rd set base frequency A303 R/W 30 to 3rd Max. frequency 1 [Hz]
3204h 3rd maximum frequency A304 R/W 30 to 400 1 [Hz]
3205h to
3215h
Not used
3216h
3rd multi-step speed
reference 0
A320
(HIGH)
R/W
0.00 to 3rd Max. frequency 0.01 [Hz]
3217h
A320
(LOW)
R/W
3218h to
323Bh
Not used
323Ch
3rd manual torque boost
voltage
A342 R/W 0.0 to 20.0 0.1 [%]
323Dh
3rd manual torque boost
frequency
A343 R/W 0.0 to 50.0 0.1 [%]
323Eh
3rd V/f characteristics
selection
A344 R/W
00: VC (Constant torque
characteristics)
01: VP (Special reduced torque
characteristics)