EasyManua.ls Logo

Omron 3G3RX - V2 Control Mode Selection

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-124
4-3 Functions When PG Option Board (3G3AX-PG01) Is Used
4
Functions
V2 Control Mode Selection
Select a control method in V2 control mode selection P012.
When "00" (ASR) is selected in P012, speed control mode is enabled. Select a frequency reference
in frequency reference selection A001.
When "01" (APR) is selected in P012, the Inverter enables position control by generating frequency
reference based on the position command pulse input from the pulse train position command input
terminal, and on the position feedback detected by the encoder.
Select any of the three pulse train position command input modes in pulse train mode selection
P013.
To perform pulse train position control, allocate "48" (STAT) to any of the multi-function input termi-
nals. While the STAT terminal is tuned on, pulse train position command input is accepted.
Position deviation can be cleared through external input. Allocate "47" (PCLR) to any of the multi-
function input terminals. Tuning on and then off the PCLR terminal can clear position deviation data.
Allocate "22" (DSE) to any of the multi-function output terminals to enable excessive speed devia-
tion signal output.
Set a deviation level in speed deviation error detection level P027. When the deviation between real
frequency and reference frequency exceeds the P027 set value, the DSE signal turns on.
When "02" (APR2) or "03" (HAPR) is selected in P012, the Inverter performs absolute position con-
trol with reference to the absolute position from its origin.
Parameter No. Function name Data Default setting Unit
P012
V2 control mode
selection
00: ASR (speed control mode)
01: APR (pulse train position control mode)
02: APR2 (absolute position control mode)
03: HAPR (high-resolution absolute position
control mode)
00
P011 Encoder pulses
128 to 65535:
Number of encoder pulses
1024 Pulse
P023 Position loop gain 0.00 to 100.00: Position loop gain 0.50 rad/s
P027
Speed deviation error
detection level
0.00 to 120.00:
DSE signal output level
7.50 Hz
H004
Motor pole number
selection
2/4/6/8/10: Select the number of motor poles. 4 Pole
C001 to C008
Multi-function inputs
1 to 8 selection
47: PCLR (position deviation clear)
48: STAT (pulse train position command input
permission)

C021 to C025
Multi-function output
terminals 11 to 15
selection
22: DSE (excessive speed deviation)
C026
Relay output (AL2,
AL1) function selection
05
Related functions A001, P013