3-56
3-9 Parameter List
3
Operation
Absolute position control
P060
Multi-step position
command 0
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
Yes
4-136
P061
Multi-step position
command 1
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P062
Multi-step position
command 2
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P063
Multi-step position
command 3
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P064
Multi-step position
command 4
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P065
Multi-step position
command 5
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P066
Multi-step position
command 6
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P067
Multi-step position
command 7
Position range specification (reverse side) to
Position range specification (forward side)
-268435455 to 268435455
0
P068 Zero return mode
00: Low speed
01: High speed 1
02: High speed 2
00 Yes
P069
Zero return direction
selection
00: FWD (Forward side)
01: REV (Reverse side)
00 Yes
P070
Low-speed zero
return frequency
0.00 to 10.00 0.00 Yes Hz
4-136
P071
High-speed zero
return frequency
0.00 to Maximum frequency 0.00 Yes Hz
P072
Position range
specification
(forward)
0 to 268435455 (at P012 = 02)
0 to 1073741823 (at P012 = 03)
268435455
Yes
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.