EasyManua.ls Logo

Omron 3G3RX - Starting Frequency; Carrier Frequency

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-68
4-2 Function Mode
4
Functions
Starting Frequency
Set the frequency for starting Inverter output when the RUN signal is turned on.
Use mainly to adjust the starting torque.
With starting frequency b082 set high, the starting current increases, possibly causing the current
to exceed the overload limit and overcurrent protection to work to trip the Inverter.
If "04" (OSLV: 0-Hz sensorless vector control) or "05" (V2: sensor vector control) is selected in
control method selection A044, this function is disabled.
Carrier Frequency
You can change the PWM waveform carrier frequency output from the Inverter.
With the carrier frequency set high, you can reduce metallic noise from the motor. However, this
increases noise or leakage current from the Inverter.
Helps avoid mechanical or motor resonance.
The maximum carrier frequency varies depending on the capacity.
To raise the carrier frequency (fc), derate the output current as shown in the following table.
Set a derating output current value as electronic thermal level.
(If the existing electronic thermal value is lower than the derating value, the above setting is not
required.)
To raise the carrier frequency, reduce the output current (or derate the rated current) as shown in
the graph below.
Parameter No. Function name Data Default setting Unit
b082 Starting frequency 0.10 to 9.99 0.50 Hz
FW
b082
Output frequency
Output voltage
Parameter No. Function name Data (HD) Data (ND) Default setting Unit
b083 Carrier frequency
0.5 to 15.0 (0.4 to 55 kW) 0.5 to 12.0 (0.4 to 55 kW) 5.0
kHz
0.5 to 10.0 (75 to 132 kW) 0.5 to 8.0 (75 to 132 kW) 3.0
Voltage 200-V class 400-V class
Capacity
Max. fc
(kHz)
Derating at fc =
12 kHz (ND)
Derating at fc =
15 kHz (HD)
Max. fc
(kHz)
Derating at fc =
12 kHz (8kHz
for 75 to 132
kW) (ND)
Derating at fc =
15 kHz (10 kHz
for 75 to 132 kW)
(HD)
0.4 kW 15 100% 100% 15 100% 100%
0.75 kW 15 100% 100% 15 100% 100%
1.5 kW 15 100% 100% 15 100% 100%
2.2 kW 15 100% 100% 15 100% 100%
3.7 kW 15 90% 100% 15 90% 100%
5.5 kW 15 100% 100% 15 100% 100%