3-25
3-9 Parameter List
3
Operation
Analog input, Others
A011 O start frequency 0.00 to 400.00 0.00 No Hz
4-14
A012 O end frequency 0.00 to 400.00 0.00 No Hz
A013 O start ratio 0 to 100 0 No %
A014 O end ratio 0 to 100 100 No %
A015 O start selection
00: External start frequency
(A011 set value)
01: 0 Hz
01 No
A016 O, O2, OI sampling
1 to 30
31 (with 500 ms filter ± 0.1 Hz hysteresis)
31 No 4-15
A017
Drive Programming
(EzSQ) Selection
0: Disable
1: [PRG] start
2: Always ON
00 No
Multi-step speed, Jogging
A019
Multi-step speed
selection
00: Binary: 16-step selection with 4 terminals
01: Bit: 8-step selection with 7 terminals
00 No 4-16
A020
Multi-step speed
reference 0
0.00 to Max. Frequency [A004] 6.00 Yes Hz
4-8
4-16
A220
* 2nd multi-step
speed reference 0
0.00 to Max. Frequency [A204] 6.00 Yes Hz
A320
* 3rd multi-step speed
reference 0
0.00 to Max. Frequency [A304] 6.00 Yes Hz
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.