EasyManua.ls Logo

Omron 3G3RX - Reduced Voltage Startup Selection; Display Selection

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-53
4-2 Function Mode
4
Functions
Reduced Voltage Startup Selection
Slowly increases voltage during motor startup.
To increase torque during startup, reduce the set value of reduced voltage startup selection b036.
Note that if the value is too small, the motor starts in full-voltage starting mode, possibly resulting
in an overcurrent trip.
Display Selection
You can change the items to be displayed on the Digital Operator.
Parameter No. Function name Data Default setting Unit
b036
Reduced voltage startup
selection
00: Reduced voltage startup disabled
01 to 255:
01: Short (approx. 6 ms)
255: Long (approx. 1.53 s)
6
Related functions b082
FW
Output
frequency
Output
voltage
Starting frequency
b082
00 01 06
Parameter No. Function name Data Default setting Unit
b037 Display selection
00: All (Complete display)
01: Utilized (Individual display of functions)
02: User (User setting)
03: Only FQ (Data comparison display)
04: Basic (Basic display)
00
U001 to U012 User selection
_ _no: No allocation
no
d001 to P196: Select the code you want to
display. (Among all codes)

Table of Contents

Other manuals for Omron 3G3RX

Related product manuals