4-186
4-4 Communication Function
4
Functions
<Holding Register Number List (Function Mode)>
1107h
Operator rotation direction
selection
F004 R/W
00: FWD (Forward)
01: REV (Reverse)
1108h
to
1200h
Not used
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Resolution
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Resolu-
tion
1201h
Frequency reference
selection
A001 R/W
00: VR (Digital Operator (FREQ adjuster))
01: Terminal
02: Digital Operator (F001)
03: RS485 (ModBus communication)
04: Option 1
05: Option 2
06: Pulse train frequency
07: EzSQ (Drive Programming)
10: (Math) Operation function result
1202h RUN command selection A002 R/W
01: Terminal
02: Digital Operator (F001)
03: RS485 (ModBus communication)
04: Option 1
05: Option 2
1203h Base frequency A003 R/W 30 to Max. frequency 1 [Hz]
1204h Maximum frequency A004 R/W 30 to 400 1 [Hz]
1205h O/OI selection A005 R/W
00: [O]/[O2] Switches between O/OI
terminal
01: [O]/[O2] Switches between O/O2
terminal AT
02: [O]/VR Switches between O/FREQ
adjuster via terminal AT
03: [OI]/VR Switches between OI/FREQ
adjuster via terminal AT
04: [O2]/VR Switches between O2/FREQ
adjuster via terminal AT
1206h O2 selection A006 R/W
0: [O2] only
1: [O/OI-P] auxiliary frequency reference
(not reversible)
2: [O/OI-PM] auxiliary frequency
reference (reversible)
3: [OFF] O2 disabled
1207h
to
120Ah
Not used
120Bh
O start frequency
A011
(HIGH)
R/W 0.00 to 400.00
0.01
[Hz]
120Ch
A011
(LOW)
120Dh
O end frequency
A012
(HIGH)
R/W 0.00 to 400.00
0.01
[Hz]
120Eh
A012
(LOW)
120Fh O start ratio A013 R/W 0 to 100 1 [%]