4-187
4-4 Communication Function
4
Functions
1210h O end ratio A014 R/W 0 to 100 1 [%]
1211h O start selection A015 R/W
00: External start frequency
(A011 set value)
01: 0 Hz
1212h O, O2, OI sampling A016 R/W
1 to 30
31: 500-ms filter with a hysteresis of
±0.1 Hz
1
1213h
Drive Programming
(EzSQ) Selection
A017 R/W
00: Disable
01: [PRG] start
02: Always ON
1213h Not used 
1214h Not used 
1215h Multi-step speed selection A019 R/W
00: Binary: 16-step selection with 4
terminals
01: Bit: 8-step selection with 7 terminals
1216h
Multi-step speed
reference 0
A020
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
1217h
A020
(LOW)
R/W
1218h
Multi-step speed
reference 1
A021
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
1219h
A021
(LOW)
R/W
121Ah
Multi-step speed
reference 2
A022
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
121Bh
A022
(LOW)
R/W
121Ch
Multi-step speed
reference 3
A023
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
121Dh
A023
(LOW)
R/W
121Eh
Multi-step speed
reference 4
A024
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
121Fh
A024
(LOW)
R/W
1220h
Multi-step speed
reference 5
A025
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
1221h
A025
(LOW)
R/W
1222h
Multi-step speed
reference 6
A026
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
1223h
A026
(LOW)
R/W
1224h
Multi-step speed
reference 7
A027
(HIGH)
R/W
0/Starting frequency to Max. frequency
0.01
[Hz]
1225h
A027
(LOW)
R/W
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Resolu-
tion

Table of Contents