4-70
4-2 Function Mode
4
Functions
Parameter Initialization
You can initialize the rewritten set values and reset to the factory default.
You can clear trip data.
You cannot clear the P100 to P131 set values, RUN time, or power ON time.
STOP Key Selection
When "control circuit terminal block" is selected for the RUN command, you can set whether the
STOP/RESET key on the Digital Operator is used to activate the STOP command and trip reset
operation.
This setting is enabled when any item other than "02" (Digital Operator) is selected in RUN
command selection A002. (Refer to "RUN Command Selection" (page 4-11).)
If "02" (Digital Operator) is selected in A002, the STOP command and trip reset operation are
enabled regardless of this setting.
Stop Selection
You can set whether the Inverter decelerates to a stop for the set deceleration time or goes into
free-run status, when the STOP command is input from the Digital Operator or the control circuit
terminal block.
Parameter No. Function name Data Default setting Unit
b084 Initialization selection
00: no (Clears the trip monitor)
01: Trip data (Initializes data)
02: Parameters (Clears the trip monitor
and initializes data)
03: Trip+Param (Clears the trip monitor
and parameters)
04: Trp+Prm+EzSQ (Clears the trip
monitor, parameters and Drive
program)
00
b085
Initialization parameter
selection
01
*Do not change.
01
b180 Initialize trigger
00: No action
01: Initialize
00
Parameter No. Function name Data Default setting Unit
b087 STOP key selection
00: ON (Enabled)
01: OFF (Disabled)
02: Only RESET (Disabled only
during stop)
00
Data
STOP command via the STOP/RESET
key on the Digital Operator
Trip reset operation via the STOP/RESET
key on the Digital Operator
00 Enabled Enabled
01 Disabled Disabled
02 Disabled Enabled