EasyManua.ls Logo

Omron 3G3RX - Frequency Jump Function; Acceleration Stop Function

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-30
4-2 Function Mode
4
Functions
Frequency Jump Function
The frequency jump function helps avoid resonant points of loaded machines.
You cannot set output frequencies within a jump frequency setting range, where the frequency
jump function avoids steady operation.
The output frequency fluctuates continuously according to the acceleration/deceleration time
during both actions.
You can set up to three points for the jump frequency.
Acceleration Stop Function
When the moment of inertia of a machine load is large, this function delays acceleration until the
motor starting slip is reduced.
Use this function, if an overcurrent trip occurs during startup.
Does not depend on acceleration pattern selection A097, and works with all acceleration patterns.
Parameter No. Function name Data Default setting Unit
A063
A065
A067
Jump frequency 1
Jump frequency 2
Jump frequency 3
0.00 to 400.00 0.00
Hz
A064
A066
A068
Jump frequency width 1
Jump frequency width 2
Jump frequency width 3
0.00 to 10.00 0.50
Related functions C001 to C008
Output frequency
A067
A065
A063
A068
A068
A066
A064
A066
A064
Frequency reference
Parameter No. Function name Data Default setting Unit
A069 Acceleration stop frequency 0.00 to 400.00 0.00 Hz
A070 Acceleration stop time 0.0 to 60.0 0.0 s
Output frequency
A069
A070
Frequency reference