3-55
3-9 Parameter List
3
Operation
Options
P046 Instance Number
0: Basic speed I/O
1: Extended speed I/O
2: Extended speed and Torque control
3: Special I/O
4: Extended control I/O
5: Extended control I/O and multifunction I/O
monitor
6: Flexible format
7: Extended speed and Acceleration control
8-20: Not used
1No
P048
Operation setting at
idle mode detection
00: Trip
01: Decel-Trip (Trip after deceleration stop)
02: Ignore
03: Free RUN
04: Decel-Stop (Deceleration stop)
00 No
P049
Polarity setting for
rotation speed
0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/
32/34/36/38
0No
P055
Pulse train frequency
scale
1.0 to 50.0 25.0 No kHz
4-144
P056
Pulse train frequency
filter time constant
0.01 to 2.00 0.10 No s
P057
Pulse train frequency
bias amount
-100 to 100 0 No %
P058
Pulse train frequency
limit
0 to 100 100 No %
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.