7-5
7-1 Standard Specification List
7
Specifications
Input
Multi-function input
8 terminals, NO/NC switchable, sink/source logic switchable
[Terminal function] 8 functions can be selected from among 61.
Reverse (RV), Multi-step speed setting binary 1 (CF1), Multi-step speed setting binary 2
(CF2), Multi-step speed setting binary 3 (CF3), Multi-step speed setting binary 4 (CF4),
Jogging (JG), DC injection braking (DB), 2nd control (SET), 2-step acceleration/
deceleration (2CH), Free-run stop (FRS), External trip (EXT), USP function (USP),
Commercial switching (CS), Soft lock (SFT), Analog input switching (AT), 3rd control
(SET3), Reset (RS), 3-wire start (STA), 3-wire stop (STP), 3-wire forward/reverse (F/R),
PID enabled/disabled (PID), PID integral reset (PIDC), Control gain switching (CAS),
UP/DWN function accelerated (UP), UP/DWN function decelerated (DWN), UP/DWN
function data clear (UDC), Forced operator (OPE), Multi-step speed setting bit 1 (SF1),
Multi-step speed setting bit 2 (SF2), Multi-step speed setting bit 3 (SF3), Multi-step
speed setting bit 4 (SF4), Multi-step speed setting bit 5 (SF5), Multi-step speed setting
bit 6 (SF6), Multi-step speed setting bit 7 (SF7), Overload limit switching (OLR), Torque
limit enabled (TL), Torque limit switching 1 (TRQ1), Torque limit switching 2 (TRQ2),
P/PI switching (PPI), Brake confirmation (BOK), Orientation (ORT), LAD cancel (LAC),
Position deviation clear (PCLR), Pulse train position command input permission (STAT),
Frequency addition function (ADD), Forced terminal block (F-TM), Torque reference
input permission (ATR), Integrated power clear (KHC), Servo ON (SON), Preliminary
excitation (FOC), Analog command on hold (AHD), Position command selection 1 (CP1),
Position command selection 2 (CP2), Position command selection 3 (CP3), Zero return
limit signal (ORL), Zero return startup signal (ORG), Forward driving stop (FOT),
Reverse driving stop (ROT), Speed/Position switching (SPD), Pulse counter (PCNT),
Pulse counter clear (PCC), No allocation (no)
Thermistor input
terminal
1 terminal (Positive/Negative temperature coefficient of resistance element switchable)
Output
Multi-function output
5 open collector output terminals: NO/NC switchable, sink/source logic switchable
1 relay (SPDT contact) output terminal: NO/NC switchable
[Terminal function] 6 functions can be selected from among 45.
Signal during RUN (RUN), Constant speed arrival signal (FA1), Over set frequency
arrival signal (FA2), Overload warning (OL), Excessive PID deviation (OD), Alarm signal
(AL), Set-frequency-only arrival signal (FA3), Overtorque (OTQ), Signal during
momentary power interruption (IP), Signal during undervoltage (UV), Torque limit (TRQ),
RUN time exceeded (RNT), Power ON time exceeded (ONT), Thermal warning (THM),
Brake release (BRK), Brake error (BER), 0-Hz signal (ZS), Excessive speed deviation
(DSE), Position ready (POK), Set frequency exceeded 2 (FA4), Set frequency only 2
(FA5), Overload warning 2 (OL2), Analog FV disconnection detection (FVDc), Analog FI
disconnection detection (FIDc), Analog FE disconnection detection (FEDc), PID FB
status output (FBV), Network error (NDc), Logic operation output 1 (LOG1), Logic
operation output 2 (LOG2), Logic operation output 3 (LOG3), Logic operation output 4
(LOG4), Logic operation output 5 (LOG5), Logic operation output 6 (LOG6), Capacitor
life warning (WAC), Cooling fan life warning (WAF), Starting contact signal (FR), Fin
overheat warning (OHF), Light load detection signal (LOC), Operation ready (IRDY),
Forward run (FWR), Reverse run (RVR), Fatal fault (MJA), Window comparator FV
(WCFV), Window comparator FI (WCFI), Window comparator FE (WCFE), Alarm codes
0 to 3 (AC0 to AC3)
Multi-function monitor
output terminal
Analog voltage output, Analog current output,
Pulse train output (A-F, D-F {multiplied by "n", pulse output only}, A, T, V, P, etc.)
Display monitor
Output frequency, Output current, Output torque, Frequency conversion value, Trip
record, I/O terminal status, Electric power, etc.
Other functions
V/f free setting (7), Upper/lower frequency limit, Frequency jump, Curve acceleration/
deceleration, Manual torque boost level/break, Energy-saving operation, Analog meter
adjustment, Starting frequency, Carrier frequency adjustment, Electronic thermal
function, (free setting available), External start/end (frequency/rate), Analog input
selection, Trip retry, Restart during momentary power interruption, Various signal
outputs, Reduced voltage startup, Overload limit, Initialization value setting, Automatic
deceleration at power-off, AVR function, Automatic acceleration/deceleration, Auto
tuning (Online/Offline), High-torque multi-motor operation control (sensor-less vector
control of two monitors with one Inverter)