App-8
Appendix-1 Parameter List
Appendix
Multi-step speed, Jogging
A038
Jogging frequency
[Jog frequency]
0.00/Starting frequency to 9.99 6.00 Yes Hz
4-18
A039
Jogging stop
selection
[Jog stop mode]
00: FRS (Free running on jogging stop/
Disabled in operation)
01: DEC (Deceleration stop on jogging stop/
Disabled in operation)
02: DB (DC injection braking on jogging stop/
Disabled in operation)
03: FRS (RUN) (Free running on jogging
stop/Enabled in operation)
04: DEC (RUN) (Deceleration stop on jogging
stop/Enabled in operation)
05: DB (RUN) (DC injection braking on
jogging stop/Enabled in operation)
04 No
V/f characteristics
A041
Torque boost
selection
[TRQ boost sel]
00: Manual torque boost
01: Automatic torque boost
00
No
4-19
A241
* 2nd torque boost
selection
[TRQ boost sel-M2]
00
A042
Manual torque boost
voltage
[TRQ boost V%]
0.0 to 20.0
1.0
Yes %A242
* 2nd manual torque
boost voltage
[TRQ boost V%-M2]
1.0
A342
* 3rd manual torque
boost voltage
[TRQ boost V%-M3]
1.0
A043
Manual torque boost
frequency
[TRQ boost FQ%]
0.0 to 50.0
5.0
Yes %
A243
* 2nd manual torque
boost frequency
[TRQ boost FQ%-M2]
5.0
A343
* 3rd manual torque
boost frequency
[TRQ boost FQ%-
M3]]
5.0
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.

Table of Contents

Other manuals for Omron 3G3RX