3-40
3-9 Parameter List
3
Operation
Others
b130
Overvoltage
protection function
selection during
deceleration
00: OFF (Disabled)
01: V-const (DC voltage kept constant)
02: Accel (Acceleration enabled)
01 No
4-78
b131
Overvoltage
protection level
during deceleration
200-V class: 330 to 390
400-V class: 660 to 780
380/
760
No V
b132
Overvoltage
protection parameter
0.10 to 30.00 1.00 No s
b133
Overvoltage
protection
proportional gain
setting
0.00 to 2.55 0.50 Yes
b134
Overvoltage
protection integral
time setting
0.000 to 65.535 0.060 Yes s
b164
Auto return initial
display
00: OFF
01: ON
00 No
b166
Data Read/Write
selection
00: R/W OK (Read/Write OK)
01: R/W Protected (Read/Write Protected)
00 No
b180 Initialize trigger
00: No action
01: Initialize
00 No
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.