Menu Description
PPS Gives the bandwidth used for each target device and total bandwidth used
for all target devices.
Set Packet Interval (RPI) for
All Connections
Changes all Packet Interval (RPI) values for all target devices.
Additional Information
You can specify a value in Set Packet Interval (RPI) for All Connections and click the Update
Button to change packet interval (RPI) values set in the connection settings for all target devi-
ces to the specified value.
l
Calculation Example for Bandwidth Used (PPS) for Each Device by the
EtherNet/IP Connections
This section describes the case where the following three EtherNet/IP connections are established
between NJ-series Controller 1 to 3, as an example of calculating the bandwidth used for each de-
vice by the EtherNet/IP connections.
Connection type Relevant devices in the EtherNet/IP connections
Device bandwidth
usage (PPS)
Connection (1) NJ-series Controller 2 (target device)
to NJ-series Controller 1 (originator device)
50 pps
Connection (2) NJ-series Controller 1 (target device)
to NJ-series Controller 2 (originator device)
10 pps
Connection (3) NJ-series Controller 3 (target device)
to NJ-series Controller 1 (originator device)
210 pps
NJ-series Controller 1
(192.168.250.1)
NJ-series Controller 2
(192.168.250.2)
NJ-series Controller 3
(192.168.250.3)
Connection (1)
EtherNet/IP network
Connection (3)
Connection (2)
Bandwidth used (PPS) for each EtherNet/IP device is as given below.
Connection (1)
Connection (3)
Appendices
A-27
NX-series EtherNet/IP Unit User's Manual (W627)
A-3 Use the Sysmac Studio to Set the Tag Data Links (EtherNet/IP Connections)
A
A-3-4 Making the EtherNet/IP Connection Settings with the Sysmac Studio

Table of Contents

Other manuals for Omron NX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX Series and is the answer not in the manual?

Omron NX Series Specifications

General IconGeneral
Programming LanguagesLadder, Structured Text, Function Block Diagram, Sequential Function Chart
Communication PortsEthernet, USB, RS-232C, RS-485
Memory CapacityVaries by model
Program MemoryVaries by model
Data MemoryVaries by model
Operating Temperature0°C to 55°C
Power Supply24 VDC
Ethernet Ports1 or 2 ports (depending on model)
USB Ports1 or 2 ports (depending on model)
DimensionsVaries by model
WeightVaries by model

Related product manuals