Parameter Reference D-67
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Heatsink Temperature
0407
Same as PNO 393
x.x
-25.0 to 200.0
°C
NEVER
Power stack heatsink temperature in
o
Centigrade.
Elec Rotor Speed
0408
Parameters::Motor Control::Feedbacks
x.x
-1500.0 to 1500.0
Hz
NEVER
Mechanical speed (shaft speed in
rev
/
s
) x number of motor pole pairs. This parameter is not filtered.