4.3.6 Port Error Disabled Configuration
This page provides to set port error disable function. The Port Error Disable Configuration screens in Figure 4-3-13 & Figure
4-3-14 appear.
Figure 4-3-13 Error Disabled Recovery Page Screenshot
The page includes the following fields:
Object Description
Recovery Interval
The period (in seconds) for which a port will be kept disabled in the event of a port
error is detected (and the port action shuts down the port).
BPDU Guard
Enable or disable the port error disabled function to check status by BPDU guard.
Self Loop
Enable or disable the port error disabled function to check status by self loop.
Broadcast Flood
Enable or disable the port error disabled function to check status by broadcast
flood.
Unknown Multicast
Flood
Enable or disable the port error disabled function to check status by unknown
multicast flood.
Unicast Flood
Enable or disable the port error disabled function to check status by unicast flood.
ACL
Enable or disable the port error disabled function to check status by ACL.
Port Security
Violation
Enable or disable the port error disabled function to check status by port security
violation.
DHCP Rate Limit
Enable or disable the port error disabled function to check status by DHCP rate
limit
ARP Rate Limit
Enable or disable the port error disabled function to check status by ARP rate limit
95

Table of Contents

Other manuals for Planet GS-4210 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet GS-4210 SERIES and is the answer not in the manual?

Planet GS-4210 SERIES Specifications

General IconGeneral
Power Input100-240VAC, 50/60Hz
EnclosureMetal
Product TypeManaged Switch
Ports24 x 10/100/1000BASE-T, 4 x 100/1000BASE-X SFP
MAC Address Table8K
Jumbo Frame9K Bytes
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% (non-condensing)
InstallationRack-mountable
Dimensions440 x 180 x 44 mm (W x D x H)
WeightGS-4210-24UP4S: 2500g