Planmeca ProMax 3
TABLE OF CONTENTS
Technical Manual
2 PREVENTIVE MAINTENANCE CHECKS ................................................... D-2
2.1 General ...................................................................................................... D-2
2.2 X-ray tube feedback system....................................................................... D-2
3 MECHANICAL CHECKS.......................................................................... D-5
3.1 Column motor nut....................................................................................... D-5
Chapter E C-ARM AND IMAGING ARM
1 REQUIRED TOOLS..................................................................................... E-1
2 PANORAMIC BEAM AND PATIENT POSITIONING
MECHANISM ADJUSTMENT..................................................................... E-5
2.1 Adjustment procedure .................................................................................E-6
2.2 Checking the panoramic beam position ......................................................E-7
2.3 Adjusting the sensor head angle...............................................................E-10
2.4 Primary collimator angle adjustment .........................................................E-12
2.5 Panoramic beam adjustment ....................................................................E-14
2.6 Patient positioning mechanism adjustment...............................................E-19
2.7 Calibration of angle sensors......................................................................E-31
2.8 Beam check ..............................................................................................E-38
2.9 Taking a ball phantom exposure ...............................................................E-39
2.10 Panoramic mode patient positioning lights................................................E-41
2.11 Adjustment of tomo mode patient positioning lights..................................E-48
2.12 Calibrating panoramic sensor head ..........................................................E-54
2.13 X-ray unit with fixed primary collimator - primary collimator adjustment ...E-55
3 PROMAX 3D: ADJUSTMENTS & CALIBRATIONS.................................... E-59
3.1 Adjustment procedure ...............................................................................E-59
3.2 Checking the connection between PCs and X-ray unit .............................E-61
3.3 Beam adjustment ......................................................................................E-62
3.4 Beam check ..............................................................................................E-68
3.5 Flat Field calibration ..................................................................................E-68
3.6 3D Geometry calibration ...........................................................................E-68
3.7 3D Quality Assurance (Q/A) Test..............................................................E-68
4 OTHER ADJUSTMENTS AND CALIBRATIONS ......................................... E-69
4.1 Calibrating the elbow arm and C-arm gear ratios .....................................E-69
4.2 Calibrating the panoramic dynamic exposure control (DEC) ....................E-71
5 REMOVING THE COVERS ...................................................................... E-77
5.1 C-arm upper covers ..................................................................................E-77
5.2 Removing the fixed sensor head holder covers ........................................E-78
5.3 Removing the movable sensor head holder covers ..................................E-80
5.4 C-arm inner cover .....................................................................................E-81

Table of Contents

Other manuals for Planmeca ProMax

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planmeca ProMax and is the answer not in the manual?

Planmeca ProMax Specifications

General IconGeneral
CategoryMedical Equipment
TypeCone Beam Computed Tomography (CBCT) System
SoftwarePlanmeca Romexis
Imaging ModesCBCT
Imaging Modalities2D Panoramic
X-ray GeneratorHigh Frequency Generator
Focal Spot Size0.5 mm
X-ray Tube Voltage60-90 kV
Exposure TimeVaries depending on imaging mode and parameters
DimensionsVaries significantly depending on model and configuration
WeightVaries significantly depending on model and configuration
Power Requirements50/60 Hz
Patient Positioningseated