Planmeca ProMax 5
TABLE OF CONTENTS
Technical Manual
3.2 Replacing the lift nut assembly ................................................................ G-18
4 REPLACING/UPGRADING SOFTWARE .................................................G-25
4.1 Replacing the CPU PCB software chips (alternative 1) ........................... G-25
4.2 Loading the software from a computer (alternative 2).............................. G-27
5 REPLACING THE BATTERY ON THE RTC PCB ........................................G-29
6 REPLACING PCBS ................................................................................. G-30
6.1 Power PCB............................................................................................... G-30
6.2 ETHERNET PCB and CPU PCB ............................................................. G-35
6.3 Input PCB................................................................................................. G-36
Chapter H CEPHALOSTAT
1 ADJUSTMENTS AND CALIBRATIONS ...................................................... H-1
1.1 Required tools ............................................................................................ H-1
1.2 Preparations before adjustments ............................................................... H-3
1.3 Checking and adjusting the sensor head and second primary
collimator mutual position........................................................................... H-4
1.4 Adjusting the sensor and second primary collimator rails .......................... H-6
1.5 Adjusting the sensor head connector and sensor head positions.............. H-7
1.6 Adjusting the height of the cephalostat .................................................... H-11
1.7 Checking the cephalostat head support position ..................................... H-14
1.8 Cephalostat head support position adjustment ........................................ H-16
1.9 Calibrating the C-arm position.................................................................. H-19
1.10 Synchronizing the scanning mechanism and first primary collimator....... H-25
1.11 Adjusting the cephalometric beam vertical position ................................. H-27
1.12 Checking the second primary collimator position..................................... H-30
1.13 Adjusting the second primary collimator position..................................... H-33
1.14 Beam check ............................................................................................. H-37
1.15 Calibrating the cephalostat sensor head.................................................. H-42
1.16 Calibrating the Cephalometric DEC ......................................................... H-49
1.17 Checking the adjustment.......................................................................... H-54
2 REMOVING AND ATTACHING THE SECOND PRIMARY COLLIMATOR H-55
2.1 Attaching the second primary collimator covers....................................... H-56
3 DETACHING AND ATTACHING THE SENSOR HEAD ............................ H-57
3.1 Cephalostat with movable sensor head ................................................... H-57
3.2 Cephalostat with fixed sensor head - removing and attaching
the sensor head ....................................................................................... H-61
4 REMOVING THE HOUSINGS AND COVERS ......................................... H-64
4.1 Removing the housings of the head support............................................ H-64
5 REPLACING PCBS ................................................................................. H-67