Planmeca ProMax 5
TABLE OF CONTENTS
Technical Manual
3.2 Replacing the lift nut assembly ................................................................ G-18
4 REPLACING/UPGRADING SOFTWARE .................................................G-25
4.1 Replacing the CPU PCB software chips (alternative 1) ........................... G-25
4.2 Loading the software from a computer (alternative 2).............................. G-27
5 REPLACING THE BATTERY ON THE RTC PCB ........................................G-29
6 REPLACING PCBS ................................................................................. G-30
6.1 Power PCB............................................................................................... G-30
6.2 ETHERNET PCB and CPU PCB ............................................................. G-35
6.3 Input PCB................................................................................................. G-36
Chapter H CEPHALOSTAT
1 ADJUSTMENTS AND CALIBRATIONS ...................................................... H-1
1.1 Required tools ............................................................................................ H-1
1.2 Preparations before adjustments ............................................................... H-3
1.3 Checking and adjusting the sensor head and second primary
collimator mutual position........................................................................... H-4
1.4 Adjusting the sensor and second primary collimator rails .......................... H-6
1.5 Adjusting the sensor head connector and sensor head positions.............. H-7
1.6 Adjusting the height of the cephalostat .................................................... H-11
1.7 Checking the cephalostat head support position ..................................... H-14
1.8 Cephalostat head support position adjustment ........................................ H-16
1.9 Calibrating the C-arm position.................................................................. H-19
1.10 Synchronizing the scanning mechanism and first primary collimator....... H-25
1.11 Adjusting the cephalometric beam vertical position ................................. H-27
1.12 Checking the second primary collimator position..................................... H-30
1.13 Adjusting the second primary collimator position..................................... H-33
1.14 Beam check ............................................................................................. H-37
1.15 Calibrating the cephalostat sensor head.................................................. H-42
1.16 Calibrating the Cephalometric DEC ......................................................... H-49
1.17 Checking the adjustment.......................................................................... H-54
2 REMOVING AND ATTACHING THE SECOND PRIMARY COLLIMATOR H-55
2.1 Attaching the second primary collimator covers....................................... H-56
3 DETACHING AND ATTACHING THE SENSOR HEAD ............................ H-57
3.1 Cephalostat with movable sensor head ................................................... H-57
3.2 Cephalostat with fixed sensor head - removing and attaching
the sensor head ....................................................................................... H-61
4 REMOVING THE HOUSINGS AND COVERS ......................................... H-64
4.1 Removing the housings of the head support............................................ H-64
5 REPLACING PCBS ................................................................................. H-67

Table of Contents

Other manuals for Planmeca ProMax

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planmeca ProMax and is the answer not in the manual?

Planmeca ProMax Specifications

General IconGeneral
CategoryMedical Equipment
TypeCone Beam Computed Tomography (CBCT) System
SoftwarePlanmeca Romexis
Imaging ModesCBCT
Imaging Modalities2D Panoramic
X-ray GeneratorHigh Frequency Generator
Focal Spot Size0.5 mm
X-ray Tube Voltage60-90 kV
Exposure TimeVaries depending on imaging mode and parameters
DimensionsVaries significantly depending on model and configuration
WeightVaries significantly depending on model and configuration
Power Requirements50/60 Hz
Patient Positioningseated