LTV
®
Series Ventilator
(LTV
®
1000, 950, and 900)
Operator’s Manual
P/N 10664, Rev. Y

Table of Contents

Other manuals for Pulmonetic Systems LTV 950

Question and Answer IconNeed help?

Do you have a question about the Pulmonetic Systems LTV 950 and is the answer not in the manual?

Summary

Chapter 1 - INTRODUCTION

Operator’s Safety Information

Information on warnings, cautions, and notes for safe operation.

Warnings

Critical safety alerts detailing potential hazards and consequences.

Cautions

Alerts regarding potential hazardous situations leading to equipment damage.

Chapter 2 - VENTILATOR OVERVIEW

Power;Supplies Required

Lists necessary power sources and supplies for operating the ventilator.

Chapter 4 - VENTILATION MODES

Chapter 5 - USING THE CONTROLS AND INDICATORS

Ventilator Controls

Overview of the front panel controls and their arrangement on the LTV® 1000 model.

Chapter 6 - CONTROLS

High Pressure Limit

Establishes the maximum pressure permitted in the patient circuit.

Chapter 7 - DISPLAYS AND INDICATORS

Vent Inop

Indicates ventilator is in the Inop state, shutting down to a safe state.

Chapter 8 - MONITORED DATA

NO CAL DATA, NO CAL Monitor Display

Alarm for invalid or missing calibration records, affecting accuracy.

Chapter 9 - VENTILATOR ALARMS

Adjustable and Critical Alarms

Ensures proper operation of all alarms, critical for patient safety.

BAT EMPTY

Indicates the internal battery is critically low; connect external power immediately.

HIGH PRES

Alarm for patient circuit pressure exceeding the High Pressure Limit setting.

HW FAULT

Indicates a hardware fault detected within the ventilator system.

INOP

Ventilator shutdown due to unsafe condition or standby state transition.

Chapter 10 - EXTENDED FEATURES

Alarm Operations

Menu to configure alarm conditions not directly available from front panel controls.

Chapter 11 - VENTILATOR CHECKOUT TESTS

Ventilator Checkout Tests

Procedures to verify proper operation of LTV® ventilator, including alarms and controls.

Alarm Test

Verifies that the audible alarm is functioning correctly.

Display Test

Verifies that the ventilator displays and LEDs are working correctly.

Control Test

Verifies that the ventilator buttons and Set Value knob are working correctly.

Leak Test

Tests the patient circuit for leaks.

Vent Inop Alarm Test

Verifies that the Inop Alarm is working correctly.

Chapter 12 - OPERATING PROCEDURE

To Turn the Ventilator On

Step-by-step guide for connecting power and initiating the ventilator startup sequence.

Before Connecting the Ventilator to a Patient

Procedures to follow before connecting the ventilator to a patient.

To Turn the Ventilator Off

Procedure for safely disconnecting the ventilator from the patient and power.

Chapter 13 - CLEANING, DISINFECTING AND STERILIZING

Cleaning the Ventilator

Instructions for cleaning the external surfaces of the ventilator with a damp cloth.

Chapter 14 - POWER AND BATTERY OPERATION

Chapter 15 - TROUBLESHOOTING

Displays and Buttons

Troubleshooting common issues related to ventilator displays and control buttons.

Ventilator Performance

Troubleshooting symptoms related to delivered volumes, pressures, and triggering.

Power and Battery Operation

Troubleshooting issues related to powering up, battery, and external power.

Alarms

Guidance on addressing recurring alarms and multiple alarm scenarios.

Appendix B - SET UP; MAINTENANCE

Recommended Maintenance Schedule

Periodic maintenance tasks recommended for the LTV® Series ventilator.

Appendix C - INSTALLATION AND CHECKOUT

Checking the Ventilator for Proper Operation

Procedure to verify ventilator functionality using checkout tests and settings.

Pulmonetic Systems LTV 950 Specifications

General IconGeneral
BrandPulmonetic Systems
ModelLTV 950
CategoryMedical Equipment
LanguageEnglish