Remote control basics
R&S
®
NRPxxS(N)
168User Manual 1177.5079.02 ─ 15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Lower limit fail
0
0
0
0
0
0
0
0
0
0
0
0
0
0
+
Figure 11-12: Operation lower limit fail status registers
Querying the register:
●
STATus:OPERation:LLFail:CONDition?
●
STATus:OPERation:LLFail[:SUMMary][:EVENt]?
Table 11-14: Used operation lower limit fail status bits and their meaning
Bit no. Short description Bit is set if
1 Lower limit fail Measured value is below the lower limit value.
11.2.5.6 Operation upper limit fail status register
The CONDition registers contain information whether a measured value currently
exceeds a configured upper limit. The EVENt registers contain information whether a
measured value exceeded an upper limit value since the last query.
Status reporting system