B-4 hsb
2
PLUS Series LCD Display
Raystar 112LP
(SeaTalk version)
Raystar 112LP (SeaTalk version)
To connect yourRaystar 112LP to your display, refer to the first illustration
belowor follow the instructionsin Chapter 8.
To connect theRaystar 112LP and your DifferentialBeacon Receiver, cut off
the5-pinconnectorand strip back the red, black and greenwires.Remove the
sleevefromtheend of theRaystar112LPcabletoexposethegreenand brown
wires,then connect to the AuxiliaryJunctionBox as shown in the second
illustration below.
CAUTION:
Ensure the correctpolarityof the 12 V supply beforeapplyingdisplay or
SeaTalk power. It is recommendedthat a multimeter is used to check the
connections.
12V
Power
Supply
(fused)
From
GPS
sensor
Yellow
Red
Screen
To Display Unit
SeaTalk Socket
D4292-3
Red
Black
12V
Power
Supply
(fused)
From
GPS
sensor
Green
Yellow
Red
Black
White
Yellow
Green
Brown
Red
Screen
To Display Unit
SeaTalk Socket
D4296-3
From
the
DBR
Red
Black
81186_3.book Page 4 Thursday, August 22, 2002 8:23 AM