6-1-8 Section 6: Installation
ST290 Instrument System Owner’s Handbook
CAUTION:
The DPU is not waterproof and so must be installed in a dry location.
The DPU must be positioned below decks in a dry location where:
• It is protected against physical damage.
• It is at least 9 in (230 mm) from a compass.
• It is at least 20 in (500 mm) from radio receiving equipment.
• There is reasonable access for installation and servicing.
Transducer Pods
Figure 1-2: Transducer Pod dimensions
CAUTION:
The transducer Pods arenot waterproofand somust be installed in a
dry location.
Each transducer Pod must be positioned below decks in a dry location
where:
• It is protected against physical damage.
• It is at least 9 in (230 mm) from a compass.
• It is at least 20 in (500 mm) from radio receiving equipment.
• There is reasonable access for installation and servicing.
2.6 in (66 mm)
4.61 in (117 mm)
1.42 in (36 mm)
D5537-1
81183_2 S6.book Page 8 Wednesday, May 7, 2003 11:27 AM