7-2-30 Section 7: System Setup
ST290 Instrument System Owner’s Handbook
Set water temperature
1. Display the GENERAL OFFSETS page.
2. Use the or button to select the WATER TEMP value field.
3. Measure the water temperature.
4. If the displayed temperature value is different from the measured
water temperature, hold down the button for 1 second to enteredit
mode. The WATER TEMP value flashes.
5. Use the or button to set WATER TEMP to the measured value.
6. Hold down the button for 1 second to save the value.
Set system voltage reading
You can set the displayed voltage reading on the ST290 system to be the
same as that at any point on the boat’s 12 V system you want to monitor,
bysettingtheST290VOLTAGE readingso it is thesame asthevoltage atthe
required point. To do this:
1. Display the GENERAL OFFSETS page.
2. Use the or button to select the VOLTAGE value field.
WARNING:
High voltages can cause death or serious injury. Always take
appropriate precautions when working with electricity. Before
accessing the electrical system, ensure you know the location of the
high voltage points and stay well clear of them.
3. Measure the voltage at the point in the boat’s 12 V electrical system
that you want to monitor.
4. If the displayed voltage value is different from the measured voltage,
hold down the button for 1 second to enter edit mode. The VOLT-
AGE value flashes.
5. Use the or button to set VOLTAGE to the measured value.
6. Hold down the button for 1 second to save the value.
81183_2 S7.book Page 30 Wednesday, May 7, 2003 1:52 PM