7-3-10 Section 7: System Setup
ST290 Instrument System Owner’s Handbook
Setting remote control configuration
The remote control setup pages enable you to define the remote group,
the sequence within the remote group and the associated Remote
Keypad(s), for an instrument.
To set the remote control configuration for any Data Display:
1. Ensure the REM GROUP page is displayed (see Figure 3-11 ). This
enables you to allocate the instrument as part of a remotely controlled
group.
2. Use the or button to allocate the instrument to the required
remote group. This can be any one of eight groups, identified by
letter, from A to H.
Figure 3-11: Set remote group
3. Press the button to move to the REM SEQUENCE page (see Figure
3-12 ).
Figure 3-12: Set remote sequence
4. Use the or button to set a number, to define the sequence in
which the instrument is selected within its remote group.
OPTIONS
REM GROUP
SETUP
D6085-1
OPTIONS
REM SEQUENCE
SETUP
D6086-1
81183_2 S7.book Page 10 Wednesday, May 7, 2003 1:52 PM