Code ‘Sro’ (C14)
Code ‘LoGn’ (C15) (iWAREHOUSE
®
Only)
Code br_o (C16)
Code Title SRO (Static Return to Off)
Operator Display 'Sro'
Error ( ) and Parameter ( ) Indicators Blinking.
System Response Truck is disabled (Emergency Reverse is Active).
Alarm Sounds No
Reason Brake is not applied when the truck is turned ON. Handle is in the brake released
range prior to the system being powered ON.
Tests to Run Confirm arm angle proximity switch function.
How to Clear Apply the brake.
Code Title Operator not Logged ON the 3rd Party Device (applies only to trucks with
iWAREHOUSE option)
Operator Display ‘LoGn’
System Response Limited to most restrictive speed if iCONTROL is enabled, otherwise no limits.
Reason Operator is not logged ON to the 3rd party supplier wireless module (SWM) device.
Tests to Run None
How to Clear Log into the iWAREHOUSE display unit.
Code Title Brake Override
Operator Display br_o
TA Flash Code “5,6”
System Response Travel, lift, and lower are disabled.
Alarm Sounds No
Reason Brake Override switch is activated to manually move the truck.
Tests to Run None
How to Clear Move the tiller arm to the upper brake position and switch the brake override
switch back to the OFF position.