EasyManua.ls Logo

Raymond 8210 - Code E232; Code E233; Code E235

Default Icon
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6. Messages and Codes Model 8210/8250 Maintenance Manual
Error Codes
6-30 Publication: 1146945/001, Revised: 25 Sep 2018
Code E232
Code E233
Code E235
Code Title VCL Runtime
Operator Display E232
TA Flash Code “6,8”
System Response No truck function active
Reason Internal TA software error.
Tests to Run None
How to Clear Cycle the truck OFF/ON. Check battery. Reload software. If unable to reload
software, replace the TA.
Code Title +5V Supply Failure
Operator Display E233
TA Flash Code “2,5”
System Response No truck function active
Reason TA +5V supply failed.
Tests to Run Check all wiring and components connected to the 12 volts from the TA for shorts.
If OK, check the wiring and encoder connected to JP1-25 for the traction motor for
shorts. See Code E230. See “Pinout Matrix” on page 8-9.
How to Clear Cycle the truck OFF/ON.
Code Title NVM Reset Error
Operator Display E235
System Response No truck function active
Reason TA NVM (Non-Volatile Memory) error. TA Non-volatile memory corrupted, unable to
reset.
Tests to Run None
How to Clear Try cycling the truck OFF/ON. If that does not solve the problem, replace the TA.
Property of American Airlines