ENERGY SAVER MODES
SM 2-77 A265/A267
Detailed
Descriptions
2.11 ENERGY SAVER MODES
2.11.1 OVERVIEW
When the machine is not used, the energy saver function reduces power
consumption by lowering the fusing temperature.
This machine has four types of energy saver mode as follows.
1) Energy saver mode (called ‘panel off mode’ in the operation manual)
2) Low power mode (called ‘energy saver mode’ in the operation manual)
3) Auto off mode (copier configuration only)
4) Night mode (copier/fax, copier/printer, copier/fax/printer configurations only)
These modes are controlled by the following UT and SP modes.
•
Energy saver timer
•
Low power timer
•
Auto off timer
•
Energy saver mode
•
Auto off disabling (UT mode only)
The way that the machine operates depends on the combination of installed
equipment (copier only, or whether a fax and/or printer is installed).
Any Status Power Off
Stand-by Mode
Auto Off Mode
Energy Saver Mode
Low Power Mode
Energy
Saver
Key
Energy Saver
Timer
Low Power
Timer
Energy
Saver Key
Ringing
Signal
Main Power
Switch Off
Main Power
Switch On
Operation
Switch On
Operation
Switch Off
Selected by
UP mode
Operation
Switch On
Operation
Switch Off
Within 3s or
10s to
return
Within 20s
or 30s to
return
Within
40~45s
to return
Energy Saver Level 1 or 2
Fusing lamp to low temp.
Energy Saver LED On
System 5V On
Fusing lamp to low
temp.
Energy Saver LED On
System 5V On
Fusing lamp Off
Energy Saver LED Off
System 5V Off
+5VE On
Night Stand-
by Mode
System 5V On
Night Mode
System 5V Off
+5VE On
-Ringing
Signal
-Off-
hook
Fax ready
conditions
Operation
Operation
Main Power Main Power Operation
Operation
Operation
Switch Off
Operation
Auto off
Timer
A267D530.WMF