FAX SC CODES
SM 7-11 A265/A267
Trouble-
shooting
A895
7.2.4 FAX SC CODE TABLE
SC Code Description
Suggested
Action
Sys Switch
1F bit 7 = 0
Sys Switch
1F bit 7 = 1
1102
Handshake error with
BiCU at start-up
1111
Command TX/RX error
to/from the BiCU
1112 Base copier’s engine was
reset
1120 Interface module error
Initialize the fax
unit.
(See section
7.2.1.for the
initialization
procedure)
Automatic
reset
1201 Unrecoverable FCU -
SRAM error
Refer to section
7.2.2.
SC Code
display
1207
Unrecoverable EXFUNC
- SRAM error
Refer to section
7.2.3.
SC Code
display
1299 Software error Turn off and on
the main switch.
1301 Original size error Check the scanner
mechanism.
1302 Scanner parameter error Initialize the fax
unit.
1303
1304
1305
1306
1308
1313
1314
1316
1318
1323
1324
1326
1328
1334
1338
Software error Initialize the fax
unit.
1401 Command timeout error -
after scanning
Initialize the fax
unit.
1402
1403
1404
Software error
Initialize the fax
unit.
1405 Command timeout error -
during storage
Check the
connection for the
FCU.
1406 Command timeout error -
original feed out
Initialize the fax
unit.
1410
1601
Software error
Initialize the fax
unit.
Automatic
reset
SC Code