OPTIONAL UNITS
SM 3-7 A265/A267
Installation
A895
3.2 OPTIONAL UNITS
3.2.1 G3 INTERFACE UNIT TYPE 270
!
CAUTION
Before installing this option, do the following:
1. If there is a printer option in the machine, print out all data in the printer
buffer.
2. Turn off the main switch and disconnect the power cord and the LAN
cable.
1. Remove the small cover [A] (1 rivet) and the rear cover [B] (4 screws). Then cut
away the jack window [C].
2. Remove the NCU unit [D] (4 screws, 2 connectors)
3. Remove the NCU [E] from the NCU unit (4 screws). Connect cable [F] to the
FCU (CN604).
If the G4 unit is not installed at the same time, go to step 6.
A895I352.WMFA895I998.WMF
A895I353.WMF
[D]
[A]
[B]
[C]
[E]
[F]

Table of Contents