ORIGINAL LENGTH, WIDTHSENSOR BOARD AND TRAILING EDGE SENSOR
SM 8-27 A265/A267
ARDF
A858
3.8 ORIGINAL LENGTH, WIDTHSENSOR BOARD AND
TRAILING EDGE SENSOR
1. Open the original table [A].
2. Remove the upper part of the table (3 screws).
3. Replace the width sensor board [B], length sensor (–1 [C] and –2 [D]) and
trailing edge sensor [E].
NOTE:
To ensure proper detection of paper size,
after wiping off the sensor board and
terminal plate with a dry cloth (or cloth with
alcohol), apply silicone grease (KS-660) to
the terminal plate [F].
A858R503.WMF
A858R504.WMF
A858R505.WMF
[A]
[B]
[C]
[D]
[E]
[F]