SERVICE PROGRAM MODE
A265/A267 4-4 SM
Accessing Copy Mode from within an SP Mode
1. Press the
'
(Interrupt) key.
2. Select the appropriate copy mode and make trial copies.
3. To return to SP mode, press the
'
(Interrupt) key again.
How to Select the Program Number
Program numbers are composed of two or three levels.
To input the required program number, select each program level in sequence.
1. Select the 1st level program number on the numeric keypad and press the
(
key or “OK” key.
NOTE:
The 1st level program number can be selected by pressing the “Prev.”
or “Next” bottom on the LCD.
2. Select the 2nd level program number at the numeric keypad and press the
(
key or “OK” key.
NOTE:
The 2nd level program number can be selected by pressing the “Prev.”
or “Next” bottom on the LCD.
3. If there any are 3rd level programs in SP mode, first enter the 2nd level SP
mode, then pressing the “Prev.” or “Next” bottom on the LCD.
To input a value or setting for an SP mode
1. Enter the required program mode as explained above.
2. Enter the required setting using the numeric keys, then press the
(
key or
“OK” key.
NOTE:
1) If you forget to press the
(
key or “OK” key, the previous value
remains.
2) Change between “+” and “–” using the
!
key before entering the
required value.
3. Exit SP mode.
Prev. Next OK Exit
SP-MODE C2 Select
Set Class 2 No 1 < Charge Bias Adjustment
[Serviceman P-Mode]
A265M509.WMF