PAPER FEED
SM 6-29 A265/A267
Replacement
Adjustment
6.6.8 REGISTRATION SENSOR
1. Remove the right cover. (See Image Density Sensor.)
2. Remove the registration guide plate [A] (2 screws).
3. Remove the paper support roller [B] (2 snap rings, 2 bushings).
4. Remove the sensor bracket [C] (1 screw).
5. Replace the registration sensor [D] (1 connector).
A267R718.WMF
[A]
[C]
[D]
[B]