BIT SWITCHES
A265/A267 4-60 SM
4.2.6 SG3 SWITCHES
This switches require an optional G3 interface unit.
SG3 Switch 00
No FUNCTION COMMENTS
0-6
Not used Do not change the settings.
7 Back to back test
0: Disabled 1: Enabled
Set this bit to 1 when you wish to do a back to
back test.
115 V model: Be sure to connect jumpers JP5
and JP6 on the NCU before doing the test.
220 V model: Be sure to apply dc voltage
between wires L1 and L2 on the NCU.
Back-to-Back Connection:
The dc power supplies should be adjusted so that the line current to the NCU is
about 30mA.
SG3 Switch 01
No FUNCTION COMMENTS
0-3
Not used Do not change the settings.
4
DIS frame length
0: 10 bytes 1: 4 bytes
1: The bytes in the DIS frame after the 4th byte
will not be transmitted (set to 1 if there are
communication problems with PC-based faxes
which cannot receive the extended DIS frames).
5
Not used Do not change the setting.
6
CED/ANSam transmission
0: Disabled
1: Enabled
Do not change this setting, unless the
communication problem is caused by the
CED/ANSam transmission.
7
Not used Do not change the setting.